Intel esb2 windows 2012

Need software for Intel ESB2 SATA RAID Controller for Windows 2012rR

‎08-10-2015 07:39 AM

  • Mark as New
  • Bookmark
  • Subscribe
  • Permalink
  • Print
  • Email to a Friend
  • Flag Post

I have installed Windows 2012r2 on my HP XW8600 and I found the software for the LSI Adapter (SAS 3000 series) but I am unable to find the software for management of the Intel ESB2 SATA RAID controller. The only software I could find was listed as a Windows 7 application but will not install onto my Windows 2012r2.

‎08-10-2015 08:43 AM — edited ‎08-10-2015 08:44 AM

  • Mark as New
  • Bookmark
  • Subscribe
  • Permalink
  • Print
  • Email to a Friend
  • Flag Post

It was not difficult to find THIS PAGE @ INTEL.com. Does this help?

Pick the Windows 2012r2 under operating system.

‎08-10-2015 10:22 AM

  • Mark as New
  • Bookmark
  • Subscribe
  • Permalink
  • Print
  • Email to a Friend
  • Flag Post

That looks exactly like the software I tried and an error reported this software will not install on this platform. I will try again tonite and see what happens. I will test all the apps on that list starting with the latest and see what happens.

I thank you for your help.

‎08-10-2015 11:40 AM

  • Mark as New
  • Bookmark
  • Subscribe
  • Permalink
  • Print
  • Email to a Friend
  • Flag Post

I am getting an error during the install of all the setuprst.exe files.

The setup program ended prematurely because of the following error:

This platform is not supported.

I am running Win 2012r2 and the intel page lists that as a operating system that is supported. The name of the device being Intel ESB2 SATA RAID Controller comes from device manager. I have not verified that is what comes with XW8600 series. I never took note of what Windows 2003 listed as the device names.

I will try to see if HP has a place that lists what was originally equiped in this model. Do you have any suggestions.

Products formerly ESB2

Need more help?

Give Feedback

Give Feedback

Our goal is to make the ARK family of tools a valuable resource for you. Please submit your comments, questions, or suggestions here. You will receive a reply within 2 business days.

Your comments have been sent. Thank you for your feedback.

Your personal information will be used to respond to this inquiry only. Your name and email address will not be added to any mailing list, and you will not receive email from Intel Corporation unless requested. Clicking ‘Submit’ confirms your acceptance of the Intel Terms of Use and understanding of the Intel Privacy Policy.

All information provided is subject to change at any time, without notice. Intel may make changes to manufacturing life cycle, specifications, and product descriptions at any time, without notice. The information herein is provided «as-is» and Intel does not make any representations or warranties whatsoever regarding accuracy of the information, nor on the product features, availability, functionality, or compatibility of the products listed. Please contact system vendor for more information on specific products or systems.

Intel technologies may require enabled hardware, software or service activation. // No product or component can be absolutely secure. // Your costs and results may vary. // Performance varies by use, configuration and other factors. // See our complete legal Notices and Disclaimers. // Intel is committed to respecting human rights and avoiding complicity in human rights abuses. See Intel’s Global Human Rights Principles. Intel’s products and software are intended only to be used in applications that do not cause or contribute to a violation of an internationally recognized human right.

Intel esb2 windows 2012

Many hardware names are usually named after the chip model, and each chip model has its own dedicated driver, so as long as you know the chip model used by the hardware, you can find the right driver. For example, if your graphics card is named: «AMD Radeon RX 580», while actually the core chip model used is: «Radeon RX 580», then enter «Radeon RX 580» or «RX 580» to find the driver.

If you have a laptop or an all-in-one PC, you can also use the product name to search, and then go to the download page which has all the drivers for this machine (including: graphics card, network card, sound card, etc.). For example, if your laptop product name is: «Dell A6-9220e Inspiron Flagship», then type «Dell A6-9220e» to find all the drivers for this laptop.

1. Enter a keyword in the input box and click the «Search» button

2. In the query results, find the driver file you need, and click the download button

• Can’t find the required driver files?
• Don’t know how to find driver files?
• Unable to download driver files due to unstable network?
You can try using this driver file finder. The method of use is very simple. The program will automatically list all the driver files available for your current system. You can install drivers for devices that do not have drivers installed, and you can also upgrade drivers to the latest driver version for devices that have already installed drivers. Click here to download the driver finder.

If you have any questions, please leave a message. We will seriously reply to every question.

Установка драйвера сетевой карты Intel I219-V в Windows Server 2008/2012/2016

Небольшое лирическое отступление.
Однажды в студеную зимнюю пору, настраивая простенький файл- сервер, столкнулся с проблемой ранее мне не встречавшейся. Удачно установил серверную ОС (это была Windows Server 2008 R2) на не серверное оборудование и уже хотел открывать шампанское, но компания intel видимо решила, что жизнь моя проходит слишком легко и беззаботно. Установив почти все драйвера, стоп-кран сработал на драйвере сетевого контроллера!

Попробовал пару раз установить драйвер разными методами и понял, что проблема в самом драйвере. Найденная на официальном сайте intel, последняя версия драйвера ситуацию никак не изменила. Все та же ошибка. Полез ковырять инет и поиск показал, что есть причина моих (и многих других людей) бед. Как оказалось, маркетологи в Intel, перетерев тему с маркетологами microsoft, решили, что позволять ставить серверные ОСи на бытовые железки, слишком щедрый жест с их стороны. Отныне, хочешь серверную операционку – купи серверную железку! Видимо, чтобы глянуть, как у потребителя пройдет привыкание к новым реалиям, решили начать с малого – сетевых контроллеров:). К счастью, серверные и персональные версии Windows похожи друг на друга, а это часто дает возможность просто модифицировать драйвер. Данный случай не исключение.

Читайте также:  Повышение приватности windows 10

Я использовал Windows Server 2008 R2 и сис.плату B150M-D3H со встроенным сетевым контроллером intel i219-v. Однако описанный метод актуален и для i217-v, и для i218-v, и для всех прочих новых сетевых intel серии PRO1000, и всех официально поддерживаемых версий ОС Windows Server.

Итак, все по порядку.

Переходим в Диспетчер устройств и смотрим ИД вашей сетевой

Я имел дело с I219-V с идентификатором поставщика и оборудования VEN_8086&DEV_15B8

Скачиваем последнюю версию драйвера intel network adapter driver с официального сайта Intel
Я не стал мелочиться и скачал Intel® Ethernet Adapters Connections CD

Распаковываем скачанный архив и переходим в PRO1000\Winx64\NDIS62 если у вас Windows Server 2008 R2. Или выбираем другую папку соответственно вашей ОС.

NDIS61 — для Windows Vista/Server 2008,
NDIS62 — для Windows 7/Server 2008 R2
NDIS63 — для Windows 8/Server 2012
NDIS64 — для Windows 8.1/Server 2012 R2
NDIS65 — для Windows 10/Server 2016

Внутри находим и открываем файл e1d62x64.inf (Для других версий Windows он соответственно будет иметь имя e1d63x64.inf, e1d65x64.inf )

Находим раздел [ControlFlags] и удаляем две строчки, что ниже [ControlFlags]

Должно получиться так

Далее в разделе [Intel.NTamd64.6.1.1] согласно ИД оборудования вашей карты ищем подходящие строки. Выделяем их и копируем в буфер

Переходим в следующий раздел [Intel.NTamd64.6.1] и в его конец вставляем скопированные строки
Должно получиться так

Сохраняем изменения и закрываем файл.

Если у вас Windows Server 2012 или более поздняя версия, то перед установкой модифицированного драйвера необходимо отключить проверку подписи драйверов. Иначе установка не пройдет. Делается это из командной строки следующими командами:

bcdedit -set loadoptions DISABLE_INTEGRITY_CHECKS
bcdedit -set TESTSIGNING ON

обязательно перезагружаем компьютер

пробуем запустить инсталляцию через установщик Autorun.exe, который находится в корне нашей распакованной папки с драйверами. Или просто указываем папку с модифицированным драйвером в случае установки через диспетчер устройств. В процессе установки появится ругань на неподписанный драйвер — как обычно, не обращаем внимания…

В итоге установка проходит без проблем.

Если у вас Windows Server 2008, то установка закончена.
Если у вас Windows Server 2012 или более поздняя версия, то необходимо снова включить проверку подписи. Делается это из командной строки следующими командами:

bcdedit -set loadoptions ENABLE_INTEGRITY_CHECKS
bcdedit -set TESTSIGNING OFF

Вот и все. Удачи…

56 Replies to “Установка драйвера сетевой карты Intel I219-V в Windows Server 2008/2012/2016”

Столкнулся с такой проблемой. Два часа не мог ни чего сделать. Нашел случайно эту статью, сделал как вы написали. И о чудо. Вы просто волшебник. Спасибо большое за совет.

Охренеть, ты красавчик))) тоже случайно совершенно наткнулся на статью!
Работает на Server 2016, проверено

Да и еще одно но у кого стоит безопасная загрузка — ничего не выйдет… а так работает

Решение для тех у кого UEFI + Безопасная загрузка:

Спасибо. Работает на W2K8 R2.

Огромное спасибо! Очень помогло!

Очень радует, что по нашей земле обетованной ходят такие люди, как автор этой статьи!
СПАСИБО!

Огромное спасибо. Столкнулся с такой проблемой. Пол дня потерял не мог ни чего сделать, все форумы прочитал, случайно наткнулся на Вашу статью, сделал как вы написали. И о чудо все заработало Спасибо большущие за совет.

Вот от всей души тебе огромное спасибо. Пол дня промучался, не мог понять в чем проблема. Долбанные капиталисты.

Гораздо проще проблема решается принудительной установкой драйвера от Intel 219-LM, это одинаковые (физически) адаптеры. И не нужно отключать цифровую подпись драйверов…. Кстати, в случае Server 2016 драйвер на 219-LM уже в составе дистрибутива 😉

Да но если на Server 2016 установить Intel 219-LM вместо Intel 219-V то система автообновления всегда будет предлагать скачть новый драйвер Intel 219-V ))) угараю над Microsoft, скачать то он скачает его, а вот устанавливать откажется ))) и так при каждом обновлении он будет предлагать

Чет у них видно руки кривые )))

Супер!
Прошелся по инструкции и решил проблему с сетевым драйвером win 2012.
Пашет !

Привет тебе, добрый человек! Висит твоя страница в закладках со времен когда я столкнулся с микротиками. Просматриваю редко, но периодично. Так вот, мучался очень давно на Win server 2016 с драйвером на i219-V. Решилось установкой драйвера от i219-LM через выбор руками. Встал, работает по сей день исправно на 1 gbit скорости. Сервер используется в качестве файлопомойки и sql сервера под 1С на 25 юзеров.

Спасибо огромное.
Помогло.
Побольше таких как ты в интернете)

Автору огромный респект.
По инструкции решил проблему на Hyper-V 2012 R2

В ТОП! Если снова пишет в HYPER-V 2016 «нет активных сетевых адаптеров» то просто понажимайте 8 и энтер несколько раз, должно помочь 😉

Большое спасибо, очень помогло

Огромное спасибо, все решилось в 2008R2 !

Добрый вечер, установил Windows server 2016 standard, RUS, 64 BIT, сделал как написано, установил драйвер, но постоянно пропадает линк и не видит сеть и нету интернета, помогите, может кто-нибудь сталкивался с такой проблемой, да , кстати, сетевуха встроенная на чипсете intel. Спасибо!

Пробуйте установкой драйвера от i219-LM через выбор руками из имеющихся в ОС драйверов.
Проверено на Windows Server 2016 Datacenter, ENG, 64 BIT

Спасибо!
Распакованный драйвер брал отсюда: https://github.com/FerdinandvHagen/I211AT-Windows-Server-2016 там уже пропатченный для I211, с этими изменениями на обе сетевушки встали дрова.

Автору громадное СПАСИБО!
На Server 2016 заработало, а ведь хотел уже внешнюю сетевуху ставить

ай спасибо тебе. server 2016 колупался несколько часов пока эту статью не увидел

Intel ESB2 SATA RAID Setup Guidelines

1 Intel ESB2 SATA RAID Setup Guidelines Intel ESB2 SATA RAID Setup Guidelines After all the hardware has been installed, you must first configure Intel ESB2 SATA RAID Settings before you install the Windows Operating System and other software drivers. Important Notes to the User: Note 1: If you do not wish to configure onboard SATA RAID functions, please go directly to Section 2 for OS Installation. Note 2: This chapter describes RAID Configuration Instructions for the Intel ESB2 RAID Controller designed for the Windows OS. 1 Introduction to Serial ATA and Parallel ATA To configure the SATA RAID functions, you must first use the Intel ESB2 SATA RAID Utility program to configure the RAID Level that you choose before installing the Windows XP/2000/2003 operating system and other software drivers. (The necessary drivers are all included on the Supermicro CD that came packaged with your motherboard.) The current version of the ESB2 SATA RAID Utility can only support Windows XP/2000/2003 Operating Systems. Serial ATA (SATA) Serial ATA (SATA) is a physical storage interface that uses a single cable with a minimum of four wires to create a point-to-point connection between devices. It is a serial link, which supports transfer rates up to 3.0 Gbps. Because the serial cables used in SATA are thinner than the traditional cables used in Parallel ATA (PATA), SATA systems have better airflow and can be installed in smaller chassis than PATA systems. In addition, the cables used in PATA are limited to a length of 40cm, while Serial ATA cables can be up to one meter in length. Overall, SATA provides better functionality than PATA. Introduction to the Intel ESB2 Serial RAID Controller Hub Located in the South Bridge of an Intel chipset, the I/O Controller Hub (ESB2) provides the I/O subsystem with access to the rest of the system. It supports an 1-channel Ultra ATA/100 Bus Master IDE controller (PATA) and six Serial ATA (SATA) ports. The ESB2 supports the following PATA and SATA device configurations: the Legacy mode and the Native mode. Page 1

Читайте также:  Windows 10 pro anahtar

2 Intel ESB2 HostRAID Setup Guidelines Intel HostRAID Configurations The following types of Intel HostRAID configurations are supported: RAID 0 (Data Striping): this writes data in parallel, interleaved («striped») sections of two hard drives. Data transfer rate is doubled if a single disk is used. RAID1 (Data Mirroring): identical data from one drive is copied to another drive. The second drive must be the same size or larger than the first drive. RAID 10 (Striping & Mirroring): RAID 0 and 1 schemes are combined (without parity information) to get the benefits of both. RAID 5: both data and parity information are striped and mirrored across three or more hard drives. Intel Matrix Storage Intel Matrix Storage, supported by the ESB2, allows the user to create RAID 0, RAID 1, RAID 10 and RAID 5 sets by using only six identical hard disk drives. The Intel Matrix Storage Technology creates two partitions on each hard disk drive, and generate a virtual RAID 0, RAID 1, RAID 10 and RAID 5 sets. It also allows you the change the HDD partition size without any data. Configuring BIOS settings for SATA RAID Functions (-the Native Mode) 1. Press the key at system boot to enter the BIOS Setup Utility. Note: If it is the first time powering on the system, we recommend you load the Optimized Default Settings. If you have already done so, please skip to Step Use the arrow keys to select the Exit Settings. Once in the Exit settings, Scroll down to select «Load Optimized Default Settings», and press the key. Select OK to confirm the selection. Press the key to load the default settings for the BIOS. 3. Use the arrow keys to select the Main section in the BIOS. 4. Scroll down to «SATA Controller Mode» and press the key to select Enhanced. 5. Scroll down to «SATA RAID Enabled» and press . Then, select «Enabled.» 6. Scroll down to Exit. Select «Exit Saving Changes» from the Exit menu. Press the key to save the changes and exit the BIOS. 7. Once you’ve exited the BIOS Utility, the system will reboot. Page 2

3 Intel ESB2 SATA RAID Setup Guidelines 8. At system boot, press the and keys simultaneously to run the Intel RAID Configuration Utility when prompted by the following message: Press for the Intel RAID Configuration Utility. Note: The Intel RAID Configuration Utility is only available for systems with two or more drives installed. The Intel RAID Utility screen will not display in systems with one drive installed. Using the Intel ESB2 SATA RAID Utility Program Creating, Deleting and Resetting RAID Volumes 1. After the system exits from the BIOS Setup Utility, the system will automatically reboot. The following screen appears after Power-On Self Test (POST) routines. 2. When you see the above screen, press the and the keys simultaneously to have the main menu of the SATA RAID Utility appear: Note: All graphics and screen shots shown in the manual are for reference only. The screen shots shown in the manual do not imply Supernicro’s endorsement or non-endorsement on any 3rd party product. Your screen may or many not look exactly the same as the graphics shown in this manual. Page 3

4 Intel ESB2 HostRAID Setup Guidelines Creating a RAID 0 Volume 1. Select «Create RAID Volume» from the main menu and press the key. The following screen will appear: 2. Specify a name for the RAID 0 set and press the key or the key to go to the next field. (You can use the key to select the previous menu.) 3. When RAID Level item is highlighted, press the and keys to select RAID 0 (Stripe) and hit . 4. When the Disks item is highlighted, press to select the HDD to configure as RAID. The following pop-up screen displays: (See the note on Page 3) 5. Use the , keys to highlight a drive and press to select it. A triangle appears to confirm the selection of the drive. 6. Use the , keys to select the stripe size, ranging from 4 KB to 128 KB for the RAID 0 array, and hit . Note: For a server, please use a lower stripe size, and for a multimedia system, use a higher stripe size. The default stripe size is 128 KB. 7. Press when «Create Volume» is highlighted. A warning message displays. 8. When asked «Are you sure you want to create this volume (Y/N), type «Y» to create the RAID volume, or type «N» to go back to the Create Volume menu. Page 4

Читайте также:  Удаленное администрирование компьютеров windows

5 Intel ESB2 SATA RAID Setup Guidelines Creating a RAID 1 Volume 1. Select «Create RAID Volume» from the main menu and press the key. The following screen will appear: 2. Specify a name for the RAID 1 set and press the key or the key to go to the next field. (You can use the key to select the previous menu.) 3. When RAID Level item is highlighted, press the , keys to select RAID 1 (Mirror) and hit . 4. When the Capacity item is highlighted, enter your RAID volume capacity and hit . The default setting is the maximum capacity allowed. 5. Press when the Create Volume item is highlighted. A warning message displays. 6. When asked «Are you sure you want to create this volume (Y/N), type «Y» to create the RAID volume, or type «N» to go back to the Create Volume menu. Page 5

6 Intel ESB2 HostRAID Setup Guidelines Creating a RAID 10 (RAID 1+ RAID 0) 1. Select «Create RAID Volume» from the main menu and press the key. The following screen will appear: 2. Specify a name for the RAID 10 set and press . 3. When RAID Level item is highlighted, use the , keys to select RAID 10 (RAID1 + RAID0) and hit . 4. When the Stripe Size is highlighted, use the , keys to select the stripe size from 4 KB to 128 KB for your RAID 10 and hit . The default setting is 64 KB. (Note: For a server, please use a lower stripe size; for a multimedia system, use a higher stripe size.) 5. When the RAID Volume Capacity item is highlighted, enter your RAID volume capacity and hit . The default setting is the maximum capacity allowed. 6. Press when the Create Volume item is highlighted. A warning message displays. 7. When asked «Are you sure you want to create this volume (Y/N), press «Y» to create the RAID volume, or type «N» to go back to the Create Volume menu. Page 6

7 Intel ESB2 SATA RAID Setup Guidelines Creating a RAID 5 Set (Parity): 1. Select «Create RAID Volume» from the main menu and press the key. The following screen will appear: 2. Specify a name for the RAID 5 set and press . 3. When the RAID Level is highlighted, use the , keys to select RAID 5 (Parity) and hit . 4. When the Disk item is highlighted, press to select the HDD to configure as RAID. The following pop-up screen displays: (See the note on Page 3.) 5. Use the , keys to highlight a drive and press to select it. A triangle appears to confirm the selection of the drive. 6. Use the , keys to select the stripe size, ranging from 4 KB to 128 KB for the RAID 5 array, and hit . (Note: For a server, please use a lower stripe size; for a multimedia system, use a higher stripe size. The default stripe size is 128 KB.) 7. Enter your desired RAID volume capacity and press when the capacity item is highlighted. The default setting is the maximum capacity allowed. 8 Press when the Create Volume item is highlighted. A warning message displays. 9. When asked «Are you sure you want to create this volume (Y/N), type «Y» to create the RAID volume, or type «N» to go back to the Create Volume menu. Page 7

8 Intel ESB2 HostRAID Setup Guidelines Deleting RAID Volume Warning: Be sure to back up your data before deleting a RAID set. You will lose all data on the disk drives when deleting a RAID set.) 1. From the Main menu, select item2-delete RAID Volume, and press . 2. Use the , keys to select the RAID set you want to delete and press . A Warning message displays. 3. When asked «Are you sure you want to delete this volume (Y/N), press «Y» to delete the RAID volume, or type «N» to go back to the Delete Volume menu. Page 8

9 Intel ESB2 SATA RAID Setup Guidelines Resetting to a Non-RAID Setting or Resetting a RAID HDD Warning: Be cautious when you reset a RAID volume HDD to non- RAID or Resetting a RAID HDD. Resetting a RAID volume or a RAID HDD will reformat the HDD, and delete the internal RAID structure on the drive. 1. From the main menu, select item3-reset Disks to Non- RAID, and press . The following screen will appear: 2. Use the , keys to highlight the RAID set drive to reset and press to select. 3. Press to reset the RAID set drive. A Warning message displays. 4. Press «Y» to reset the drive, or type «N» to go back to the main menu. Exiting the Intel Matrix Storage Manager Utility 1. From the main menu, select item4-exit, and press . A warning message will appear. 2. Press «Y» to reset the drive, or type «N» to go back to the main menu. Page 9

10 Intel ESB2 HostRAID Setup Guidelines 2 Installing the Windows XP/2000/2003 OS with RAID Functions Installing a New Operating System-the Windows XP/2000/2003 OS 1. Insert Microsoft’s Windows XP/2000/2003 Setup CD in the CD Driver, and the system will start booting up from CD. 2. Press the key when the message-» Press F6 if you need to install a third party SCSI or RAID driver» displays. 3. When the Windows XP/2000/2003 Setup screen appears, press «S» to specify additional device(s) you want to select. 4. Insert the driver diskette-«intel AA RAID XP/2000/2003 Driver for ESB2 into Drive A: and press the key Choose the Intel(R) ESB2 SATA RAID Controller from the list indicated on the XP/2000/2003 Setup screen, and press the key. Press the key to continue the installation process. (If you need to specify any additional devices to be installed, do it at this time.) Once all devices are specified, press the key to continue with the installation. From the Windows XP/2000/2003 Setup screen, press the key. The XP/2000/2003 Setup will automatically load all device files and then, continue the Windows XP/2000/2003 installation. 8. After Windows XP/2000/2003 Installation is completed, the system will auto- matically reboot. Note: the current version of the ESB2 SATA RAID Utility can only support the Windows XP/2000/2003 Operating System. Page 10

Оцените статью