Penmount windows universal driver windows 10

AMT / Proprietary software and hardware R&D, comprehensive quality control, flexible and customized service, provides customers with convenient one stop shop service.

Certified resistive, projected capacitive (PCAP) touch screens and PenMount touch screen controllers meeting international standards, ISO, UL E331240-A1-UL, REACH, and RoHS. All touch screen products are supplied with flexible production quantity and long term support. Over 20 year experience in touch panel industry. Supplies resistive and projected capacitive touch panels, touch controllers, LCDs, optical bonding, open frame touch monitors, touch display products. Based in Taiwan, AMT is a manufacturer of resistive and projected capacitive (PCAP) touch screens, and PenMount touch screen controllers for the industrial, medical, and commercial sectors. since 1998.

amt1@amtouch.com.tw

Product Category

Products

AMT touch products encompass a wide range of items and services from touch panel hardware to controller software customization services. As the world’s only company supplying both proprietary touch panels and proprietary controllers, our standard solution includes a resistive or projected capacitive (PCAP) touch panel paired with a PenMount control board and software that allows for effortless integration. This is just the beginning. Your project will have limitless potential with the support of AMT’s product line and services.

Touch Screen Display Solution

A Touch Screen Display Solution (TDS) is ideal for embedded applications and offers maximum flexibility.

Open Frame Touch Screen Monitor

The AMT Open Frame Touch Monitor is a production ready, drop in solution to add an industrial grade multi-touch.

Optical Bonding Service

AMT provides in-house optical bonding of our projected capacitive (PCAP) touch screens and resistive.

Projected Capacitive Touch Screen Solutions

AMT has made significant investments in the research and development of Projected Capacitive touch screens.

Resistive Touch Screen Solutions

AMT hold our products to the highest standard and offer comprehensive before and after-sales services.

Over 20 Years Resistive | PCAP Touch Screen | PenMount Touch Screen Controller Manufacturing — AMT

Located in Taiwan, Apex Material Technology Corporation, since 1998, is a manufacturer of resistive and projected capacitive (PCAP) touch screens, and PenMount touch screen controllers. Main products, including open frame touch screen monitor, optical bonding service, solutions for touch screen display, projected capacitive touch screen and resistive touch screen. Touch screen products and solutions particularly for medical, outdoor, public commercial and transportation industries.

Certified (ISO, UL E331240-A1-UL, REACH, and RoHS) resistive, projected capacitive (PCAP) touch screens and PenMount touch screen controllers meeting international standards. All touch screen products are supplied with flexible production quantity and long term support.

AMT has been offering customers high-quality resistive and projected capacitive (PCAP) touch screens, and PenMount touch screen controllers, both with advanced technology and 30 years of experience, AMT ensures each customer’s demands are met.

Based in Taiwan, AMT is a manufacturer of resistive and projected capacitive (PCAP) touch screens, and touch screen controllers for the industrial, medical, and commercial sectors.

Mission & Vision

AMT is dedicated to quality. AMT’s unique value lies in its ability to fulfill the diverse needs of customers.

Environmental & Energy Policy

AMT is committed to environmental conservation and the perpetuation of green energy.

Quality Certification

AMT has obtained ISO 9001: 2015, ISO 14001: 2015, ISO 50001:2011, ISO 45001:2018, UL E331240-A1-UL, REACH, and RoHS certifications.

Penmount windows universal driver windows 10

Windows Embedded System ▼GO

Linux System ▼GO

PenMount Windows Universal 2000 / XP / 2003 / Vista / 2008 / 7 / 8 / 10 Driver.

PenMount Windows Universal Driver V2.4.4.345 Release date : 2015/08/05 ▼ ECN

1. PenMount Windows Universal Driver V2.4.4.345 passes Windows 7 / 8.1 32/64 bit hardware certification (WHQL).

2. install.ini adds new option «ForceInstall» to force install RS-232 driver to non PnP mode .

3. install.ini adds new section [beep] to setup default beep setting.

4. PMonitor.exe: Display file version in the file property menu.

5. RButton: This utility will often check and bring itself to the topmost position, to avoid being covered by other windows such as the Windows Media Player.

6. Digitizer mode adds beep function.

7. When install the PenMount driver depend on the PenMount PCI product support to 5 touches.

8. When install the PenMount driver still support PCI «Abnormal Report» state report.

9. Several modifications are applied to PenMount RS-232 device driver

a. Fix beep in digitizer mode. pen down and pen up timing was switched.

b. When using «Mouse Emulation Mode», device driver will not send left button event after press and hold right button event is sent.

c. In non PnP mode, if no device is attached, the PenMount Control Panel will display PenMount 6000 firmware parameters with «-1» value to avoid confusion.

d. Supports updating firmware with device driver installed.

10. Several modifications are applied to PenMount usb device driver

a. Fix pen input emulation acts like mouse emulation mode when right button emulation is disabled.

b. Fix a compatibility issue when using press and hold for right click during system running burn in software, might cause touch failure.

c. EEPROM will store RefScreenOrientation, the screen degree when doing calibration.

PenMount Windows Universal Driver V2.4.2.325 Release date : 2014/03/28 ▼ ECN▼Download

1. Fix an issue in V2.4.1.320, where PM6005 reboot to BIOS, but firmware calibration not enabled.

2. The PenMount Control Panel supports Clear Calibration Data.

3. PenMount 6000 firmware configurations now also saved to EEPROM.

4. Fix an issue in V2.4.1.320, where installation non PnP RS-232 device will fail on COM ports without using upperfilter.

5. In PenMount Control Panel, the «standard calibration» for PM6005 V2.1 is for 5 point firmware calibration.

6. Fix an issue in V2.4.1.320 and earlier PenMount USB drivers, where cycling the USB hub power will cause touch not functioning.

7. Fix an issue in V2.4.1.320 PenMount RS-232 driver, where PenMount P2 becomes single touch only after system resume from suspend or hibernation.

8. PenMount mouse drivers now uses WDF 1.9 runtime library, these files increase the overall size of the PenMount device driver package.

PenMount Windows Universal Driver V2.4.1.320 Release date : 2013/10/31 ▼ ECN▼Download

1. PenMount Windows Universal Driver V2.4.1.320 passes Windows 7 / 8.1 32/64 bit hardware certification (WHQL).

2. Support PM6005 controller with USB and RS-232 interface.

3. Support PM1450 controller and off-screen button settings.

4. Solve the issue where default driver setting in penmount.ini is not applied in 64 bit systems.

5. Solve the issue when device driver is installed in mouse mode and multiple monitors are used, touching on the right screen edge will make mouse cursor jump to the left side of screen.

6. Display rotation is now supported when using PenMount PCI controllers with mouse mode.

Читайте также:  Smtp почтовый сервер для windows

7. Solve the issue when using RS-232 interfaces, mouse cursor will jump to previous touched positions when touching the (0,0) point.

8. Support firmware calibration with PM6005 controllers.

a. USB: firmware calibration is disabled after device driver is installed, device driver will use software calibration instread.

b. RS-232: firmware calibration is disabled when using 9/16/25 point calibration mode, device driver will use software calibration instread.

c. Both USB and RS-232 interface shares the same firmware calibration data.

9. Several modifications are applied to PenMount USB device driver.

a. If multiple controllers are used, user can assign one to be the main controller. Other controllers will be disabled when touching with the main controller.

b. The on screen keyboard is available in log-in screen, even when device is installed in mouse mode.

c. An issue is solved when call calibration UI using command prompt.

d. An issue is solved which the calibration tab of PenMount Control Panel is not available if the device driver fails to retrieve firmware verison.

PenMount Windows Universal Driver V2.4.0.306 Release date : 2012/10/30 ▼ ECN▼Download

1. PenMount Windows Universal Driver V2.4.0.306 passes Windows 7 / 8 32/64 bit hardware certification (WHQL).

2. In Windows XP Tablet PC Edition / Vista / 7 / 2008 / 8, during the installation procedure, a dialog box will show up and prompt user for selecting mouse or digitizer mode.

3. Detecting all COM ports automatically, driver V2.4.0.306 will be installed only if PenMount PNP or non-PNP device exists. Improving V2.2.0.283 default installations at COM1 and COM2, which leads to the incapability of other RS232 devices.

4. Correcting the problem that the calibration data can’t be stored in EEPROM when installing PenMount non- PnP driver for PenMount PnP device.

5. Obtaining the needed system HID driver automatically in Windows XP Embedded.

6. For the non- supporting languages, the installation program runs in English automatically.

7. Correcting PenMount Gesture setting combinations for resolving the problem that the default is restored after re- booting. The default of V2.4.0.306 is not to install PenMount Gestures.

8. Correcting PenMount Gestures recognize directions opposite after the screen rotation.

9. Adding Digitizer AP to read FirmwarePara.ini default.

10. Adding the speed adjusting function for Double Click, which is applied for all the mouse devices of the system.

11. Correcting the problem that Microsoft right key menu appears while calibrating in Windows XP tablet.

12. Changing the mouse operating mode among 4 operating modes in RS232 driver: pressing the right key long, the data are sent sequentially: left down, left up, right down, right up, left down, the last “left down” is removed in V2.4.0.306.

13. Resolving the problem that the system gives stop command when installing PCMCIA card in Windows 7 which causes no working of PenMount 6000.

14. Adding to read the correspondent operation mode parameters stored in install.ini when running “Back To Default” function. It can resolve the problem that the operation mode goes back to the default when changing USB port while using USB interfaces.

15. The inaccuracy problem after the screen rotation is resolved: after screen rotation, deleting registry or changing USB port for PenMount device then re-booting it, the inaccuracy occurred.

16. In the multi- screen setting process, it will skip automatically after waiting for 10 seconds.

17. New function: the option of saving the calibration data when the calibration is failed.

18. Correcting the wrong setting values of the edge compensation after rotation in PenMount Digitizer.

19. The correspondent RS-232 driver outer parameters are added.

20. The touch disability problem has been resolved: When using RS-232 interface, after continuous and rapid clicks on PenMount device icon in the PenMount control panel, may cause touch control misconfigured and may stop working.

21. Adding the function of calling Buzzer in Windows XP 64 bits / 7 32_64 bits.

22. Correcting the phenomenon for multi- screen that drawing lines to an edge, the cursor jumps to another side of the screen and the lines drag.

23. In Windows XP 64 bits system, it’s able to turn off the blue dot confirmation page while making calibration.

PenMount Windows Universal Driver V2.2.0.283 Release date : 2010/02/23 ▼ ECN▼Download

1. PenMount Windows Universal Driver V2.2.0.283 has got the “Compatible with Windows 7” logo for both 32 bit and 64 bit systems.

2. New power management options: User can choose to turn on USB selective suspend feature on Windows Vista and Windows 7. Microsoft recommends USB devices to support this feature. However, after selective suspend is turned on, the touch screen might not response immediately. This might be a bad user experience, so this feature is turned off by default.

3. Touch screen is operated as touch digitizers in Windows Vista and Windows 7. In touch digitizer mode, PenMount hands over some of its features to the system, and only provides functions below:

a. Touch screen calibration.

b. Edge compensation.

d. PenMount gestures.

e. Firmware information.

4. The device drivers logs useful events for debugging. If developers need this information, they can check them out in the Event Viewer.

5. The gesture icons in the PenMount Gesture AP have been changed.

6. The PenMount Gesture AP has a new sensing time option.

7. If the PenMount installation process does not find any serial devices, a message box will show up to remind users to check if they have set the settings correctly.

PenMount Universal Driver V2.1.0.263 Release date : 2009/07/31 ▼ ECN▼Download

1. W hen update the state of the PenMount 6000 RS-232 device by using the refresh button in PenMount Control Panel, if follow the unplug, refresh, plug in , refresh step, the device will be shown but the driver won’t send any touch inputs in V2.1.0.234 is now fixed.

2. When switching the modes of “Right Mouse Button” between showing on desktop and task bar, the mode selection in the PenMount Control Panel will be shown correctly now.

3. The PenMount Control Panel will always show the “Advanced Calibration” options, therefor the “Open Advanced Calibration” button is hidden, and the “4 point advanced calibration” used in V2.1.0.234 has been set to the default calibration option.

4. Add single touch gesture support.

5. Support screen rotation of Intel Embedded Graphics Driver.

6. Improve hand writing line smoothness.

7. The default value of edge compensation has been changed to 5.

PenMount Windows Universal Driver V2.1.0.234 Release date : 2008/12/22 ▼ ECN▼Download

1.This driver has n’t been summited to Microsoft’s Windows XP 32 / 64-Bit, Vista 32 / 64-Bit WHQL certification yet.

2.The double click function is disabled by default. In driver version 2.1.0.207, users might find that they can’t draw lines when double click feature is enabled..

3.Correct a bug in version 2.1.0.207, when using PM6000RS-232 and PM9000 with 9600bps, the baud rate detection may failed after switching between the about and edge compensation panel several times.

4.Correct a bug in version 2.1.0.207, when calling the calibration utility with command line and using extended desktop , the reference points will move across screens.

Читайте также:  Как работать с пакетом линукс

5.Amended 6000 USB / RS-232 12 bit abnormal movements and calibration can not be effectively completed.

6.Amended a bug in driver version 2.1.0.207. When using Windows XP 64bit Edition and enabling and the screen rotation monitoring function, some windows might be brought to top and cover the rotation reference point after rotation occurs.

7.This driver supports both PenMount 6000 and PenMount 9000 non-PNP devices.

PenMount Windows Universal Driver V2.1.0.207 Release date : 2008/07/25 ▼ ECN▼Download

1.All of the Windows XP 32-Bit and Vista 32 / 64-Bit driver have been Certificated by WHQL for PenMount 6000, 9000 and 5000 Series Controllers.

2.Removed the Beep function via PC-Speaker on Windows XP-64Bit & Vista 64-Bit operating system.

3.Added the function of cursor direction match with display angle correctly on Windows XP 64-Bit operating system.

4.Correct the status of “Turn off EEPROM storage” setting for PenMount 9000 and PenMount 6000 RS232 controllers.

5.Added the function of cursor direction match with display angle correctly. Even display output is not at zero degree when PenMount driver was installing on Windows XP 32 / 64-Bit and Vista 32 / 64-Bit operating system.

PenMount Windows Universal Driver V2.1.0.187 Release date : 2008/05/23 ▼ ECN▼Download

1.The Microsoft WHQL has failed since all drivers have been modified.

2.Contract the reference points for advanced calibration and add the edge compensation feature.

3.New device detection feature.

4.Modify the press and hold feature for right button emulation.

5.Touch position is now correct when doing screen rotation on VIA VGA chip set.

6.Touch position is now correct when local machine is logged in by remote user using the Remote Desktop Connection.

7.No mapping is needed when triggering the dual screen touch mode.

8.The FIFO value is now correctly set for RS-232 PenMount devices.

PenMount Windows Universal Driver V2.0.0.113 Release date : 2007/12/04 ▼ ECN▼Download

1.Modified the word of German and Italian language.

PenMount 9000 Windows 98 / Me Driver.

PenMount 9000 Windows 98-Me Beta Driver V3.2 Release date : 2003/10/03 ECN▼Download

1.Add beep sound adjust function.

2.Add operation mode select function.

PenMount 9000 Windows 98-Me Driver V3.1 Release date : 2003/07/28ECN

Add wake up function from suspend .

PenMount 9000 Windows 98-Me Driver V3.0 Release date : 2003/02/11ECN▼Download

1.Add advanced calibration function .
2.Support ATI display driver rotate function .

PenMount 9000 W indows 98-Me Driver V2.2 Release date : 2002/07/24 ECN▼Download

Modify portrait function .

PenMount 9000 Windows NT Driver.

PenMount 9000 Windows NT V1.1 Release date : 2004/09/07 ECN

Support PM9036 and PM90A4 Control Board.

Modify uninstall problem..

Modify portrait function .

PenMount Windows XP Embedded Universal Driver. ∆ TOP

PenMount Windows XP Embedded Universal DriverV2.4.1.321 Release date : 2014/01/16 ▼ ECN

1. PenMount Windows XP Embedded Universal Driver V2.4.1.321 passes Windows 7 / 8.1 32/64 bit hardware certification (WHQL).

2. Support PM1450 controller and off-screen button settings.

3. Solve the issue where default driver setting in penmount.ini is not applied in 64 bit systems.

4. Solve the issue when device driver is installed in mouse mode and multiple monitors are used, touching on the right screen edge will make mouse cursor jump to the left side of screen.

5. Display rotation is now supported when using PenMount PCI controllers with mouse mode.

6. Solve the issue when using RS-232 interfaces, mouse cursor will jump to previous touched positions when touching the (0,0) point.

7. Several modifications are applied to PenMount USB device driver.

a.If multiple controllers are used, user can assign one to be the main controller. Other controllers will be disabled when touching with the main controller.

b.The on screen keyboard is available in log-in screen, even when device is installed in mouse mode.

c.An issue is solved when call calibration UI using command prompt.

d.An issue is solved which the calibration tab of PenMount Control Panel is not available if the device driver fails to retrieve firmware verison.

PenMount Windows XP Embedded Universal Driver V2.4.0.307 Release date : 2012/12/10 ECN▼Download

1. PenMount Windows Universal Driver V2.4.0.307 passes Windows hardware certification (WHQL).

2. When update the state of the PenMount 6000 RS-232 device by using the refresh button in PenMount Control Panel, if follow the unplug, refresh, plug in , refresh step, the device will be shown but the driver won’t send any touch inputs in V2.1.0.238 is now fixed.

3. When switching the modes of “Right Mouse Button” between showing on desktop and task bar, the mode selection in the PenMount Control Panel will be shown correctly now.

4. The PenMount Control Panel will always show the “Advanced Calibration” options, therefor the “Open Advanced Calibration” button is hidden, and the “4 point advanced calibration” used in V2.1.0.238 has been set to the default calibration option.

5. Support screen rotation of Intel Embedded Graphics Driver.

6. Improve hand writing line smoothness.

7. Two operation modes are added: “Pen Input Emulation” and “Click On Release”.

8. The default value of edge compensation has been changed to 5.

9. Detecting all COM ports automatically, driver V2.4.0.307 will be installed only if PenMount PNP or non-PNP device exists.

10. Correcting the problem that the calibration data can’t be stored in EEPROM when installing PenMount non- PnP driver for PenMount PnP device.

11. Adding the speed adjusting function for Double Click, which is applied for all the mouse devices of the system.

12. Changing the mouse operating mode among 4 operating modes in RS232 driver: pressing the right key long, the data are sent sequentially: left down, left up, right down, right up, left down, the last “left down” is removed in V2.4.0.307.

13. Adding to read the correspondent operation mode parameters stored in install.ini when running “Back To Default” function. It can resolve the problem that the operation mode goes back to the default when changing USB port while using USB interfaces.

14. The inaccuracy problem after the screen rotation is resolved: after screen rotation, deleting registry or changing USB port for PenMount device then re-booting it, the inaccuracy occurred.

15. New function: the option of saving the calibration data when the calibration is failed.

16. The correspondent RS-232 driver outer parameters are added.

17. The touch disability problem has been resolved: When using RS-232 interface, after continuous and rapid clicks on PenMount device icon in the PenMount control panel, may cause touch control misconfigured and may stop working.

18. Adding the function of calling Buzzer in Windows XP 64 bits.

19. Correcting the phenomenon for multi- screen that drawing lines to an edge, the cursor jumps to another side of the screen and the lines drag.

20. In Windows XP 64 bits system, it’s able to turn off the blue dot confirmation page while making calibration.

PenMount Windows XP Embedded Universal Driver V2.1.0.238 Release date : 2009/01/20 ECN▼Download

1. This driver hasn’t been summited to Microsoft’s Windows XP / Vista WHQL certification yet.

Читайте также:  Настройки компьютера windows media

2. Contract the reference points for advanced calibration and add the edge compensation feature.

3. Modify the press and hold feature for right button emulation.

4. Touch position is now correct when doing screen rotation on VIA VGA chip set.

5. Removed the Beep function via PC-Speaker on Windows XP-64Bit & Vista 64-Bit operating system.

6. Added the function of cursor direction match with display angle correctly on Windows XP 64-Bit operating system.

7. Added the function of cursor direction match with display angle correctly. Even display output is not at zero degree when PenMount driver was installing on Windows XP / Vista operating system.

8. Correct a bug in version 2.1.0.207, when using PM6000RS-232 and PM9000 with 9600bps, the baud rate detection may failed after switching between the about and edge compensation panel several times.

9. Correct a bug in version 2.1.0.207, when calling the calibration utility with command line and using extended desktop , the reference points will move across screens.

10. Amended 6000 USB / RS-232 12 bit abnormal movements and calibration can not be effectively completed.

11. Amended a bug in driver version 2.1.0.207. When using Windows XP 64bit Edition and enabling and the screen rotation monitoring function, some windows might be brought to top and cover the rotation reference point after rotation occurs.

12. This driver supports both PenMount 6000 and PenMount 9000 non-PNP devices.

PenMount Windows XP Embedded Universal Driver V2.0.0.107 Release date : 2007/12/06 ECN▼Download

PenMount WinCE Driver.

PenMount WEC7_WEC2013_ x86_ARM_MIPSII Stylus Driver V4.4 Release date : 2013/08/15ECN▼Download

1. This device driver package supports PenMount 6000, PenMount 9000, PenMount P2. In the catalog file, there are two options, allow user to choose USB or RS-232 interface. Unlike to the V3.4 device driver, only stylus version is supported.

2. Supports both WEC 7 and WEC 2013 platforms.

3. A memory leak issue in previous device driver, which happens when touching has been resolved.

PenMount WinCE7.0 x86 and ARM7 stylus Driver V4.0 Release date : 2011/11/03ECN▼Download

1. Support WEC 7 system.

PenMount WinCE5.0_6.0 x86_ARM_MIPSII Driver V3.4.2 Release date : 2013/08/15 ECN ▼Download

1. This device driver package supports PenMount 6000, PenMount 9000, and PenMount P2 series. In the catalog file, there are four options, allow user to choose USB or RS-232 interface, and choose standard or stylus versions.

2. The calibration utility in both Standard and Stylus versions has been updated to support the PenMount 4 and 9 calibration algorithm. The calibration pointshave been moved inwardly from screen edges, and the range is also adjustable.

3. Edge compensation is supported and adjustable from registry.

PenMount Serial / USB WinCE x86 and ARMV4I Driver V3.3 Release date : 2010/03/01ECN▼Download

PenMount Serial WinCE5.0 x86 and ARMV4I Driver V3.3
PenMount Serial WinCE5.0 x86 and ARMV4I stylus Driver V3.3
PenMount Serial WinCE6.0 x86 and ARMV4I Driver V3.3
PenMount Serial WinCE6.0 x86 and ARMV4I stylus Driver V3.3
PenMount USB WinCE5.0 x86 and ARMV4I Driver V3.3
PenMount USB WinCE5.0 x86 and ARMV4I stylus Driver V3.3
PenMount USB WinCE6.0 x86 and ARMV4I Driver V3.3
PenMount USB WinCE6.0 x86 and ARMV4I stylus Driver V3.3
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download

1 . Simplify the initialization in device drivers, therefor improve system start up time.

2. Improve the advanced calibration algorithm, and will produce smoother lines when drawing.

3. Fix the issue when using controllers with empty EEPROM, the touch pointer will not move until performing the calibration process.

PenMount Serial / USB WinCE x86 and ARMV4I Driver V3.2Release date : 2009/07/15 ECN▼Download

PenMount Serial WinCE5.0 x86_ARMV4I Driver V3.2
PenMount Serial WinCE5.0 x86_ARMV4I stylus Driver V3.2
PenMount Serial WinCE6.0 x86_ARMV4I Driver V3.2
PenMount Serial WinCE6.0 x86_ARMV4I stylus Driver V3.2
PenMount USB WinCE5.0 x86_ARMV4I Driver V3.2
PenMount USB WinCE5.0 x86_ARMV4I stylus Driver V3.2
PenMount USB WinCE6.0 x86_ARMV4I Driver V3.2
PenMount USB WinCE6.0 x86_ARMV4I stylus Driver V3.2
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download

1. When disable reading calibration data from EEPROM, the driver will call RegFlushKey function on system starts , which will slow down the startup speed.

2. When disable reading calibration data from EEPROM and choose the standard calibration in the pmser STD driver, the driver will set the MaxADX value to MaxADY by mistake, as a result the Y axis is always in wrong position.

3. When setting any of the hardware switch on PenMount 5000 series control board to OFF, the driver will ignore all the touch inputs.

PenMount Serial / USB WinCE x86 and ARMV4I Driver V3.1 Releasedate : 2009/01/20 ECN▼Download

PenMount Serial WinCE5.0 x86_ARMV4I Driver V3.1
PenMount Serial WinCE5.0 x86_ARMV4I stylus Driver V3.1
PenMount Serial WinCE6.0 x86_ARMV4I Driver V3.1
PenMount Serial WinCE6.0 x86_ARMV4I stylus Driver V3.1
PenMount USB WinCE5.0 x86_ARMV4I Driver V3.1
PenMount USB WinCE5.0 x86_ARMV4I stylus Driver V3.1
PenMount USB WinCE6.0 x86_ARMV4I Driver V3.1
PenMount USB WinCE6.0 x86_ARMV4I stylus Driver V3.1
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download

1. Correct a bug that will make PenMount touch function fails when using PenMount 6000 USB controllers with firmware 6000.6.0.0.

2. Correct a bug when using advance calibration, the driver will save the registry with wrong values.

PenMount Serial / USB WinCE x86 and ARMV4I Driver V3.0 Release date: 2008/07/31ECN▼Download

PenMount Serial WinCE5.0 x86_ARMV4I Driver V3.0
PenMount Serial WinCE5.0 x86_ARMV4I stylus Driver V3.0
PenMount Serial WinCE6.0 x86_ARMV4I Driver V3.0
PenMount Serial WinCE6.0 x86_ARMV4I stylus Driver V3.0
PenMount USB WinCE5.0 x86_ARMV4I Driver V3.0
PenMount USB WinCE5.0 x86_ARMV4I stylus Driver V3.0
PenMount USB WinCE6.0 x86_ARMV4I Driver V3.0
PenMount USB WinCE6.0 x86_ARMV4I stylus Driver V3.0
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download
▼Download

PenMount 6000 USB WinCE4.2 Driver V1.2 Release date : 2009/07/15ECN

PenMount 6000 USB WinCE4.2 Driver V1.2
PenMount 6000 USB WinCE4.2 Stylus Driver V1.2
▼Download
▼Download

1. Support PenMount 6000 Firmware 6000.6.0.0.

PenMount CentOS 5.0-5.5 Driver V3.5.0 Release date : 2010/10/19 ECN

Fix the BUG that can’t work in CentOS 5.0 and 5.1.

1. Add some function in PenMount UI interface : 4 kinds of operating mode, smooth when draw, beep setting, draw test, right button setting, edge compensation.

2. Merge PenMount CentOS 5.0, 5.1, 5.2, 5.3, 5.4, 5.5 driver.

PenMount Ubuntu 10.04 Driver V3.6.1 Release date : 2010/11/30 ECN

1. Add the hot- plug function.

2. Add the auto-corresponding for screen rotating 90 o and 270 o using xrandr V1.3.2.

3. Corrected the inaccurate problem when turn off ” Use press and hold as right click” immediately after the calibration.

PenMount Ubuntu 10.04 Driver V3.0.2 Release date : 2010/07/28 ECN▼Download

1. Fix the calibration issue.

2. Support RandR V1.3.

PenMount Ubuntu 10.04 Driver V3.0.1 Release date : 2010/05/04 ECN▼Download

PenMount Fedora 13 Driver V3.6.1 Release date : 2010/11/30 ECN

1. Add the hot- plug function.

2. Add the auto-corresponding for screen rotating 90 o and 270 o using xrandr V1.3.2.

3. Corrected the inaccurate problem when turn off ” Use press and hold as right click” immediately after the calibration.

PenMount Fedora 13 Driver V3.0.3 Release date : 2010/0 8/03 ECN▼Download